We know how Web GuidingBusiness Unit TireVideo Web InspectionPrint ManagementPrint Defect DetectionRegister Control

Search:

Newsletter:

Login:


Contact

Contact our web guiding experts here.

Brochure

Products │ Web Guiding │ Commander │ ekrPro family │ ekrPro Com60

ekrPro Com60

The ekrPro Com60 provides maximum versatility and greatest flexibility. This is possible via fieldbus gateways (Profibus DP, DeviceNet, CANopen) integrated into the controller housing. These Bus-Gateways make it possible to easily connect all current popular bus systems and equipments used by customers.

 

State of the art engineering in the smallest space

The compact size of the new controllers allows them to be fitted directly on or inthe guiding device. The graphic LCD display on the front plate show the operating status of the controller as well as the bus status and the web width (sensor positioner application).


Applicable sensing systems:

  • Ultrasonic sensor
  • Infrared sensor
  • Line sensor for contrast sensing (line or edge)
  • Reflection sensor
  • CCD camera

Sensor positioner (fields of application): 

  • Prepositioning
  • Web width measurement
  • Web edge guiding
  • Center-line guiding

Technical data

  • Supply voltage: 24 V DC
  • Functions:
    • Guiding to the right web edge
    • Guiding to the left web edge
    • Guiding to the center-line
    • Guiding to printed lines or edges
    • Watch dog function
  • Analog inputs:
    • 4 x 0... ± 10 V or 0... + 10 V, individual variable
    • 2 x 0... ± 9,75 V or 0... + 9,75 V, individual variable
    • 1 x Namur adaptation with output
  • Analoge output: ± 10 V
  • Digital inputs: (24 V):
    • Controller release
    • Remote controle (16 inputs)
  • Digital outputs: (24 V):
    • 4 digital outputs to drive hydraulic valves


Powerful actuators:

  • Direct connection of the complete actuator range from      EMS 5 to EMS 20, with or without position feedback.
  • Realisation of higher actuating forces is possible at any time via modular extension.
  • Realisation of hydraulic actuating systems (hydraulic cylinder) by actuating a plunger coil or a servo valve.

Technical data

  • Status signal: Voltage free contact „system ok“,

       max. 30 V, 2 A

  • Interface: 2 x BST CANopen Bus,
    optional
    • Profibus DP-Modul
    • DeviceNet-Modul
    • CANopen-Modul
  • Operating conditions:
    • Temperature: 0 to max. 45°C (32 to 113° F)
    • Humidity of air: 0 – 90 %,  non-condensing
  • Material of housing: Metall
  • Weight: ca. 2,1 kg (4,6 lbs)
  • Protection class: IP 54
  • Dimensions: